Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Winter 2005
Volume 7 , Issue 4



Pages: 297-302
Back
Share Abstract:

Microtensile Bond Strength of Current Dentin Adhesives Measured Immediately and 24 Hours After Application

Tranchesi Sadek,Fernanda/Goracci, Cecilia/Capel Cardoso, Paulo Eduardo/Tay, Franklin R./Ferrari, Marco

Purpose: To evaluate the immediate microtensile bond strengths achieved with representative adhesive systems from each of the four current bonding approaches. Materials and Methods: Resin composite was bonded incrementally to flat, midcoronal dentin from 33 human molars, using the adhesives (Adper Scotchbond MP; Adper Scotchbond 1; Optibond Solo Plus; Clearfil SE Bond; AdheSE; Tyrian SPE + One Step Plus; Optibond Solo Plus self-etching; One-Up Bond F; iBond; Adper Prompt L-Pop; Xeno III) according to the respective manufacturer’s instructions. The bonded specimens were immediately sectioned into sticks and underwent microtensile bond testing either immediately or after 24 h. Data were analyzed with two-way ANOVA and LSD tests. Results: No significant differences were found between immediate and 24-h bond strengths (p > 0.05). However, significant differences were observed among adhesives (p = 0.001). The all-in-one adhesive iBond showed statistically lower values when compared to all the other adhesives. Adper Prompt L-Pop, Xeno III, Tyrian SPE + One Step Plus and One-Up Bond F, all self-etching adhesives, were significantly weaker than AdheSE, Optibond Solo Plus, Adper Scotchbond 1, Optibond Solo Plus self-etching, Clearfil SE Bond, and Adper Scotchbond MP, which did not differ statistically from each other. Conclusion: Microtensile bond strengths of representative adhesive systems from the four categories of bonding agents were not equivalent, with the lowest values recorded for the one-step self-etching adhesives. There were no differences in the bond strengths when measured immediately and after 24 h.

Keywords: microtensile bond strength, dentin, adhesive system, test period

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog