Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

September/October 2006
Volume 8 , Issue 5



Pages: 319-325
Back
Share Abstract:

Shear Bond Strength of Different Adhesives to Er:YAG Laser-prepared Dentin

Celik, Esra Uzer / Ergücü, Zeynep / Türkün, L. Sebnem / Türkün, Murat

Purpose: The aim of this study was to examine the influence of Er:YAG laser on the shear bond strength of three different adhesives to lased dentin. Materials and Methods: Seventy specimens obtained from 35 extracted human molars were embedded in polyester resin and ground with silicon carbide papers. The samples were divided into seven groups. 1. Er:YAG laser (Key Laser 3, KaVo) + Clearfil Protect Bond (Kuraray); 2. Er:YAG laser + Clearfil tri-S Bond (Kuraray); 3. Er:YAG laser + 37% H3PO4 + Single Bond 2 (3M-ESPE); 4. Er:YAG laser + Single Bond 2; 5. conventional method + Clearfil Protect Bond; 6. conventional method + Clearfil tri-S Bond; 7. conventional method + 37% H3PO4 + Single Bond 2. The samples were subjected to shear bond testing 24 h after bonding. Statistical analyses were carried out by two-way ANOVA, t-test, one-way ANOVA, post-hoc Tukey’s and Dunnett C test (p = 0.05). Results: Only the Er:YAG laser + Clearfil tri-S Bond group demonstrated significantly higher bond strengths vs conventionally prepared specimens (p < 0.05). There were no significant differences between the shear bond strengths of Single Bond 2 adhesive applied to laser- vs bur-treated specimens (p > 0.05). In laser prepared samples, Clearfil Protect Bond showed the highest scores (p < 0.05), whereas in conventionally prepared groups, no statistical differences were observed between Clearfil Protect Bond and Clearfil tri-S Bond (p > 0.05). Conclusion: Er:YAG laser irradiation did not adversely affect the shear bond strength of Single Bond 2 and Clearfil Protect Bond to dentin, whereas it increased the shear bond strength values of Clearfil tri-S Bond.

Keywords: Er:YAG laser, antibacterial adhesive, all-in-one adhesive

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog