Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

September/October 2006
Volume 8 , Issue 5



Pages: 293-298
Back
Share Abstract:

Bond Strength of Resin-based Restorations Polymerized with Different Light-curing Sources

D’Alpino, Paulo H. P. / Wang, Linda / Rueggeberg, Frederick A. / Svizero, Nádia R. / Pereira, José C. / Pashley, David H. / Carvalho, Ricardo M.

Purpose: To evaluate the influence of different light-curing units on microtensile bond strength of resin composite restorations. Materials and Methods: Standardized Class I preparations (6.0 x 4.5 mm, 2.5 mm deep) were made in extracted human third molars after abrading the cusps. Resin was inserted in bulk using a 3M ESPE restorative system [Adper Single Bond (DBA)/ Filtek Z250 (RC)]. Both materials were polymerized using different light-curing units: QTH at 540 mW/cm2 (XL 3000, 3M ESPE); LED at 750 mW/cm2 (Elipar FreeLight2, 3M ESPE); PAC at 2130 mW/cm2 (Arc Light II, Air Techniques). Nine different light combinations were developed to polymerize both DBA and RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Restored teeth were stored in distilled water for 24 h at 37°C and then sectioned, yielding stick-shaped specimens with a bonded area of approximately 0.9 mm2. Specimens were assessed in a testing machine at a crosshead speed of 1 mm/min. The results were analyzed using two-way ANOVA and Tukey’s test at a pre-set α = 0.05. Results: The combinations PAC/QTH and QTH/QTH presented the highest bond strength values, and LED/QTH the lowest (p < 0.05). Significantly lower values were observed in combinations when the LED light was used to polymerize DBA compared to QTH and PAC lights, irrespective of the light source used to polymerize RC (p < 0.05). Same light combinations presented similar bond strength values. Conclusions: Different light sources influence restoration bond strength. Bond strength is more dependent on the light source used for DBA than for curing RC.

Keywords: light-curing units, microtensile bond strength, adhesive system, resin composite

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog