Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

March/April 2009
Volume 11 , Issue 2

Pages: 117-125
Back
Share Abstract:

Effects of Nd:YAG Laser Irradiation on the Hybrid Layer of Different Adhesive Systems

Ferreira, Leila S. / Ferreira, Lisiane Soares / Francci, Carlos / Navarro, Ricardo Scarparo / Calheiros, Fernanda Calabró / Eduardo, Carlos de Paula

Purpose: The aim of this in vitro study was to evaluate the microtensile bond strength (μTBS) and hybrid layer morphology of different adhesive systems, either followed by treatment with Nd:YAG laser irradiation or not. Previous studies have shown the effects of Nd:YAG laser irradiation on the dentin surface at restoration margins, but there are few reports about the significance of the irradiation on the hybrid layer. Materials and Methods: The flattened coronal and root dentin samples of 24 bovine teeth were randomly divided into 8 groups, according to the adhesive system used – Scotchbond Multi Purpose (SBMP) or Clearfil SE Bond (CSEB) – and were either irradiated with Nd:YAG or not, with different parameters: 0.8 W/10 Hz, 0.8 W/20 Hz, 1.2 W/10 Hz, 1.2 W/20 Hz. The left sides of specimens were the control groups, and right sides were irradiated. A composite crown was built over bonded surfaces and stored in water (24 h at 37°C). Specimens were sectioned vertically into slabs that were subjected to μTBS testing and observed by SEM. Results: Control groups (27.81 ± 1.38) showed statistically higher values than lased groups (21.37 ± 0.99), and CSEB control group values (31.26 ± 15.71) were statistically higher than those of SBMP (24.3 ± 10.66). There were no significant differences between CSEB (20.34 ± 10.01) and SBMP (22.43 ± 9.82) lased groups. Among parameters tested, 0.8 W/10 Hz showed the highest value (25.54 ± 11.74). Nd:YAG laser irradiation caused dentin to melt under the adhesive layer of both adhesive systems tested. Conclusion: With the parameters used in this study, Nd:YAG laser irradiation of the hybrid layer promoted morphological changes in dentin and negatively influenced the bond strength of both adhesive systems.

Keywords: adhesion, dentin, microtensile bond strength, Nd:YAG laser, scanning electron microscopy

Full Text PDF File | Order Article

 

 
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog