Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

July/August 2009
Volume 11 , Issue 4

Pages: 305 - 309
Back
Share Abstract:

Effect of Radiotherapy on the Microleakage of Adhesive Systems

Bulucu, Bilinc / Avsar, Aysun / Demiryürek, Ebru Özsezer / Yesilyurt, Cemal

Purpose: The aim of this in vitro study was to evaluate the effect of radiotherapy on the microleakage of three adhesive systems: a one-step self-etching, a two-step self-etching, and an etch-and-rinse system. Materials and Methods: Box-shaped Class V cavity preparations were prepared on the buccal surfaces of 84 extracted human molars. The molars were randomly assigned into 6 groups (n = 14) according to the irradiation and adhesive system as follows: G1, Clearfil S3 Bond (irradiated); G2, Clearfil SE Bond (irradiated); G3, Prime & Bond NT (irradiated); G4, Clearfil S3 Bond (nonirradiated); G5, Clearfil SE Bond (nonirradiated); and G6, Prime & Bond NT (nonirradiated). The cavities were restored with composite resin (Filtek Z 250). After restoration of the samples, a total dose of 60 Gy was delivered in 2 Gy/d fractions for 5 days per week for 6 weeks for the related groups. All specimens were thermocycled for 200 cycles between 5°C and 55°C using a dwell time of 60 s in each bath and then placed in 0.5% basic fuchsin solution for 24 h at room temperature. Specimens were then rinsed and sectioned; the dye penetration at the enamel and dentin margins was examined using a stereomicroscope, and a score of 0 to 3 was assigned. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U-tests. Results: No statistically significant difference existed between the irradiated and nonirradiated groups (p > 0.05). Significant differences in microleakage were observed between enamel and dentin (p < 0.01). The microleakage at the dentin margins was greater than at the enamel margins. Prime & Bond NT revealed statistically significantly (p < 0.05) higher leakage scores in dentin than did ClearfilS3 Bond and Clearfil SE Bond. Conclusion: Within the limitations of this study, irradiation application did not affect the microleakage of dental adhesive systems.

Keywords: dental adhesives, irradiation, radiotherapy, microleakage