Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
Official Web Site
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Prof. Dr. Roland Frankenberger, Prof. Bart Van Meerbeek

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

July/August 2016
Volume 18 , Issue 4



Pages: 317–323
PMID: 27419244
DOI: 10.3290/j.jad.a36516
Back
Share Abstract:

Evaluation of Bond Strength, Marginal Integrity, and Fracture Strength of Bulk- vs Incrementally-filled Restorations

Fernanda Silva de Assis / Suellen Nogueira Linares Lima / Mateus Rodrigues Tonetto / Shilpa H. Bhandi / Shelon Cristina Souza Pinto / Pamela Malaquias / Alessandro D. Loguercio / Matheus Coelho Bandéca

Purpose: This study evaluated the effect of application technique and preparation size on the fracture strength (FS), microtensile bond strength (μTBS) and marginal integrity (MI) of direct resin composite restorations.

Materials and Methods: Conservative (5 × 2 × 2 mm) or extended (5 × 4 × 2 mm) preparations below the cementoenamel junction were performed in 140 human maxillary premolars (n = 70 per group). After adhesive application (XP Bond), half of each group was restored with the bulk technique (one 4-mm increment of Surefill SDR Flow plus one 1-mm horizontal capping layer of TPH3 [Spectrum TPH3 resin composite]) and half incrementally (TPH3 in three horizontal incremental layers, 1.5 to 2 mm each), all using a metal matrix band. After storage (24 h at 37ºC), the proximal surfaces of each tooth were polished with Sof-Lex disks. For FS measurement, 60 restorations were mounted in a universal testing machine and subjected to a compressive axial load applied parallel to the long axis of the tooth, running at a crosshead speed of 0.5 mm/min. For μTBS testing, 40 teeth were longitudinally sectioned to obtain resin-dentin bonded sticks from the cavity floor (bonded area: 0.8 mm2). Specimens were tested in tension at 0.5 mm/min. The external marginal integrity of both proximal surfaces was analyzed using SEM of epoxy resin replicas. The μTBS, marginal integrity, and fracture resistance data were subjected to two-way ANOVA, and Tukey’s post-hoc test was used for pair-wise comparisons (α = 0.05).

Results: Fracture resistance, microtensile bond strength, and marginal integrity values were not statistically significantly affected by application technique or preparation size (p = 0.71, p = 0.82, and p = 0.77, respectively).

Conclusions: The use of a bulk-fill flowable composite associated with a conventional resin composite as a final capping layer did not jeopardize the fracture strength, bond strength to dentin, or marginal integrity of posterior restorations.

Full Text PDF File | Order Article

 

 

  © 2019 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog