Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

May/June 2013
Volume 15 , Issue 3



Pages: 237-243
PMID: 23534012
DOI: 10.3290/j.jad.a28623
Back
Share Abstract:

3D Assessment of Void and Gap Formation in Flowable Resin Composites Using Optical Coherence Tomography

Nazari, Amir / Sadr, Alireza / Shimada, Yasushi / Tagami, Junji / Sumi, Yasunori

Purpose: To investigate the effect of composite type and cavity size on gap and void formation using optical coherence tomography (OCT). Materials and Methods: Class I cavities of two depths (2 mm or 4 mm; 4 mm diameter) were prepared, treated with Tri-S Bond (Kuraray Medical), and bulk filled with either Surefil SDR Flow (SF; Dentsply) or Clearfil Majesty LV (MJ; Kuraray Medical) to form four groups. After 24 h, the specimens were 3D scanned using swept-source OCT (Santec) with 1310 nm laser at a 20 kHz sweep rate. In OCT tomograms, the bonding interface and the bulk of the restorations were evaluated. The percentage values of sealed interfaces (SP) and void volume (VP) for all groups were calculated and statistically analyzed using two- and one-way ANOVA and Tukey’s post-hoc test. Selected specimens were cross sectioned and observed using a scanning electron microscope (SEM) and a confocal laser scanning microscope to confirm OCT findings. Results: The following values were obtained for SP and VP, respectively: SF-2mm: 92% and 0.08%; SF-4mm: 66% and 0.13%; MJ-2mm: 86% and 1.79%; MJ-4mm: 33% and 1.96%. Both composites showed a significant increase in gap formation at 4-mm cavity depth (p < 0.001). While SF showed a rather homogeneous bulk compared to MJ, cavity depth did not significantly affect the void volume fraction (p = 0.08). Conclusion: The flowable composite with SDR (stress-decreasing resin) technology performed better than the conventional composite; however, bulk filling a 4-mm-deep cavity will compromise the sealing of the bonding interface regardless of the type of composite. OCT is a unique method of characterizing materials and their behaviors nondestructively and precisely.

Keywords: void, gap, flowable resin composite, OCT, SDR

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog