Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

July/August 2011
Volume 13 , Issue 4



Pages: 367 - 373
Back
Share Abstract:

Influence of Preparation Design on Failure Risks of Ceramic Inlays: A Finite Element Analysis

Ona, Masahiro / Watanabe, Chie / Igarashi, Yoshimasa / Wakabayashi, Noriyuki

Purpose: To assess the influence of preparation design on failure risk of ceramic inlays by means of finite element (FE) analysis. Materials and Methods: Both 2D and 3D models of the maxillary first premolar were constructed. MOD ceramic inlays were designed with an isthmus width of 1.5 to 5.0 mm and a minimum thickness of 1 to 3 mm. Occlusal contact motion and debonding at the tooth/ceramic adhesive interface were simulated in 2D models by downward displacement of a ceramic ball (1.5 mm in diameter) onto the central groove. The stress distributions within the inlays and at the interface were analyzed using 3D models. A maximum occlusal load of 250 N was assumed. Results: The maximum principal stress at the base of the inlays was constant among models of different isthmus widths, although it decreased considerably as inlay thickness increased from 1 mm to 2 mm. The maximum shear stress at the adhesive interface increased as the width of the inlay decreased and the distance between the occlusal contact and the margin decreased to 0.3 mm or less. The maximum principal stress on the occlusal surface was relatively low and insensitive to inlay design; however, it was increased by a simulated adhesive failure. Conclusion: The failure risk at the base of the inlay is minimized by increasing the minimum inlay thickness. As the occlusal contact becomes close to the margin, the adhesive failure risk is increased, potentially leading to an increase in risk of fracture on the occlusal surface.

Keywords: ceramic inlay, preparation design, failure risk, finite element analysis

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog