Simple System to Record Jaw Movements by a Home Digital Camcorder

Soichiro Kinuta, DDS/Kazumichi Wakabayashi, DDS, PhD/Taiji Sohmura, DEng/Tetsuya Kojima, DDS, PhD/Mitsumasa Nagao, DDS, PhD/Takashi Nakamura, DDS, PhD/Junzo Takahashi, DEng

Pages: 563–568
PMID: 14651246

Purpose: Systems of recording jaw movements that are used in prosthodontics and orthodontics are too expensive and complicated for daily clinical diagnosis. This pilot study presents the development of a simple system using a camcorder and motion-capturing software. Materials and Methods: Markers to detect jaw movement were attached to the mandibular incisors of a subject. A mirror was assembled beside the subject’s face to detect anteroposterior movement. Jaw movements were recorded by a home digital camcorder. Movements of the markers were analyzed by motion-capturing software and transferred to 3-D data. The results were compared with those of a conventional system. To examine the accuracy of the measurements, the markers were placed on a computer-controlled x-y working stage and displaced. The positions of the markers were measured and analyzed, then compared with the true values indicated by the x-y working stage. Results: The trajectories of the mandibular incisors recorded by the new system were very similar to those of the conventional system. On measurement accuracy, the mean differences between the measured and true values of the vertical and transverse movements were 0.07 mm (SD 0.03) and 0.06 mm (SD 0.04), respectively. On anteroposterior movement, the difference was 0.11 mm (SD 0.05). Conclusion: This new system can be useful for simple recording of jaw movements with satisfactory accuracy. Int J Prosthodont 2003;16:563–568.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog