Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
May/June 2003
Volume 16 , Issue 3

Back
Share Abstract:

A Randomized Clinical Trial Comparing Two Mandibular Implant Overdenture Designs: 3-Year Prosthetic Outcomes Using a Six-Field Protocol

Joanne N. Walton, DDS, FRCD(C)

Pages: 255260
PMID: 12854788

Purpose: This clinical trial tested the null hypothesis that there would be no difference in prosthetic maintenance for two-implant mandibular overdentures retained by either a bar-clip mechanism or ball attachments. Prosthetic outcomes are reported over 3 years using a six-field protocol. Materials and Methods: One hundred edentulous participants received new maxillary complete dentures and a mandibular two-implant overdenture (IOD), with random assignment to either a bar and metal clip or two ball attachments (titanium alloy matrix and spring) for retention. Eighty-seven subjects were available for follow-up after 3 years. Results: Almost three times as many bar-clip dentures (63%) were rated successful compared to the ball attachment design. Two percent of the participants in each group died over the course of the study, while 15% of the bar-clip and 8% of the ball IOD subjects were lost to follow-up. More than three times as many ball attachment IODs (60%) required retreatment in the form of excessive repairs, and twice as many of the ball attachment design (8%) required replacement. The ball attachment IOD was significantly more likely to require patrix tightening or matrix replacement, while the barclip design was more likely to require activation of the matrix. Conclusion: Using the criteria of a six-field protocol for implant overdenture outcomes, the bar-clip IOD was a significantly more successful prosthesis, requiring less maintenance than the titanium alloy matrix and spring ball attachment IOD employed in this study. The null hypothesis was therefore defeated. Int J Prosthodont 2003;16:255260.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog