Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
May/June 2011
Volume 24 , Issue 3

Back
Share Abstract:

Clinical Performance and Material Properties of Single-Implant Overdenture Attachment Systems

Nabeel H.M. Alsabeeha, DMD, MSc, MFDS RCPS, PhD/Michael V. Swain, BDS, PhD/Alan G.T. Payne, BDS, MDent, DDSc, FCD

Pages: 247–254
PMID: 21519573

Purpose: The aim of this study was to evaluate the mechanical properties of different attachment systems used for mandibular single-implant overdentures and to compare their wear/deformation features with clinical performance in patients after 1 year. Materials and Methods: Three attachment systems were evaluated: large 5.9-mm titanium nitride–coated ball attachments with plastic matrices, standard 2.25-mm uncoated titanium alloy ball attachments with Dalla Bona–type gold alloy matrices, and Locator attachments of titanium nitride–coated patrices and nylon matrices. The hardness and elastic modulus of the systems were determined using the nanoindentation technique. Twelve attachments from each system were used in 36 edentulous patients to support mandibular single-implant overdentures. After 1 year, 5 samples from each system were retrieved and evaluated for wear changes under a scanning electron microscope. Results: The titanium nitride–coated patrices, regardless of system, appeared unchanged and did not require any maintenance. Extensive wear was evident in the uncoated titanium alloy patrices and Dalla Bona–type gold alloy matrices, resulting in high maintenance (15 activations). Minimal wear was observed in the plastic matrices with minimal maintenance (2 replacements). The Locator nylon matrices showed extensive deformation and deterioration with a substantial need for maintenance (16 replacements). The performance of the patrices was related to hardness, while that of the matrices was related to the creep response. Conclusions: Large ball attachment systems of titanium nitride–coated patrices and plastic matrices reflect favorable wear behavior and clinical performance. These attachments are recommended for patients receiving mandibular single-implant overdentures. Int J Prosthodont 2011;24:247–254.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog