LOGIN
 
Share Page:
Back

Volume 15 , Issue 3
May/June 2002

Pages 223–229


Influence of Framework Design on Fracture Strength of Mandibular Anterior All-Ceramic Resin- Bonded Fixed Partial Dentures

Spiridon Oumvertos Koutayas, Dr Med Dent, DDS, CDT, Matthias Kern, Dr Med Dent, PhD, Franco Ferraresso, CDT, Jörg Rudolf Strub, Dr Med Dent, PhD


PMID: 12066484

Purpose: The purpose of this in vitro study was to evaluate the influence of the framework design on the fracture strength of all-ceramic resin-bonded fixed partial dentures (RBFPD) in the mandibular incisor region. Materials and Methods: Twenty-four aluminum oxide ceramic frameworks were copy milled with the Celay system, glass infiltrated, and veneered with feldspathic porcelain to replace a mandibular incisor. Forty-eight extracted human incisors were used as abutments by embedding them in a polyester resin. The master casts were fabricated according to a typical clinical case. The sandblasted restorations were bonded to the acid-etched abutment teeth with a composite resin. Twelve RBFPDs had a conventional two-retainer design, and 12 had a cantilevered single-retainer design. Subgroups of eight specimens were subjected to a quasistatic load in the direction of the long axis of the abutment teeth in a universal testing machine. Additional subgroups of four specimens were subjected under 0 degrees to dynamic loading of 25 N in a dual-axis chewing simulator. Results: The mean fracture strengths under quasistatic loading were 313 N (SD 42) for the two-retainer design and 291 N (SD 100) for the single-retainer design. The mean cycles sustained by specimens subjected to dynamic loading at 25 N were 50,081 (SD 42,705) for the two-retainer design and 297,099 (SD 508,439) for the single-retainer design. There was no statistically significant influence of the framework design on the fracture strength of the restorations under quasistatic or dynamic loading. Conclusion: The clinical application of cantilevered all-ceramic RBFPDs in the mandible may be an alternative to all-ceramic RBFPDs with two retainers. Int J Prosthodont 2002;15:223–229.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help