LOGIN
 
Share Page:
Back

Volume 6 , Issue 6
November/December 1993

Pages 585-591


Marginal Fit of Restorations Before and After Cementation In Vivo Volume 7 (1994)

Kern/Schaller/Strub


PMID: 8148031

Triturated luting cements provide convenient clinical handling. This study clinically evaluated the influence of two trituration capsule cement systems on the marginal fit of inner copings for telescoping crowns. Using a randomized parallel design, one coping was cemented using zinc phosphate cement (Phosphacap) and one using a glass-ionomer cement (Ketac-Cem Maxicap) for each of 12 patients. A blind examination of the marginal fit of the restorations was made before and after cementation using the replica technique and a scanning electron microscope. The mean marginal discrepancies for all cast copings were approximately 30 microns (median 23 microns) before cementation. They increased significantly after cementation to 86 microns (median 63 microns) in the zinc phosphate cement copings but to only to 47 microns (median 44 microns) in the glass-ionomer cement copings.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 