Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
July/August 1993
Volume 6 , Issue 4

Back
Share Abstract:

Three-Dimensional Analysis of the Casting Accuracy of One-Piece, Osseointegrated Implant-Retained Prostheses

Tan/Rubenstein/Nicholls/Yuodelis

Pages: 346-363
PMID: 8240646

The three-dimensional distortions of implant frameworks of two designs, reflecting the early Toronto U-shaped design and a current L-shaped design, were measured. A conventional commercial laboratory one-piece casting method, using a silver-palladium alloy, was used. Distortion was defined by five displacement variables for the centroids of each of five gold cylinders incorporated in each casting: three orthogonal translational displacements (dx, dy, and dz) and two rotational displacements (d theta x and d theta y). A computerized coordinate measuring machine was used. Overall translational displacements measured were -17.4 +/- 15 microns for dx, 6.1 +/- 7.1 microns for dy, and -0.1 +/- 1.7 microns for dz. The overall global translational displacement, dR, was 20.2 +/- 14.5 microns. Overall rotational displacements were -0.098 +/- 0.109 degrees for d theta x and -0.020 +/- 0.097 degrees for d theta y, giving an average absolute angular change, d theta R, of 0.158 +/- 0.077 degrees. No significant differences were found between U- and L-shaped castings, except for dy values for cylinders 2, 3, and 4, and d theta x values for cylinder 1. Cylinder location within the arch was associated with a specific direction and magnitude of translational and rotational displacement. Even small rotational displacements may manifest large gap appearances with the one-screw test because of the moment arm effect. However, other rotational displacements may be hidden, depending on the direction of tilt and the moment arm length.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog