Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
November/December 1998
Volume 11 , Issue 6

Back
Share Abstract:

A 3- to 6-Year Study of Overdentures Supported by Hydroxyapatite-Coated Endosseous Dental Implants

Watson/Ogden/Tinsley/Russell/Davison

Pages: 610-619
PMID: 10023225

Purpose: The purpose of this study was to evaluate the clinical effectiveness of hydroxyapatite-coated cylindrical implants to support overdentures. These implants were placed between 1990 and 1994 and have been followed up over a period of 3 to 6 years. Materials and Methods: One hundred thirty-nine Calcitek dental implants were placed in 43 patients to support 14 maxillary and 30 mandibular overdentures. Standardized clinical review procedures were used. Results: At exposure all the implants were found to be osseointegrated. To date only 7 implants (5%) have completely failed and two associated overdentures (5%) have been lost. The cumulative survival rate of all implants over 6 years was 92%. However, if failure is defined by the loss of more than 4 mm of cervical bone, 33 implants could be classified as being in the process of failing. Using these figures, interval success rates as low as 82% were found by year 6, and the cumulative success rate would fall to 39%. Maxillary survival and success rates were siginficantly lower than mandibular rates, at 38% and 10%, respectively, by year 5. Conclusion: Failure rates were higher in the maxillary arch, in poor quality bone, in smokers, and where implants were opposed by a natural dentition or an implant-supported prosthesis. The results suggest that the cervical bone level adjacent to the Calcitek cylindrical hydro xyapatite-coated implant failed to establish a steady state, particularly in the maxillary arch. Doubts remain regarding the long-term prognosis of these cylindrical implants.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog