Cemented Single Crowns on Osseointegrated Implants after 5 Years: Results from a Prospective Study on CeraOne


Pages: 212-218
PMID: 9728114

Purpose: The aim of this prospective study was to present the results after 5 years of loading of 65 CeraOne (Nobel Biocare) crowns. Materials and Methods: Sixty-two implants in the maxilla and 3 implants in the mandible were placed in 57 patients. Sixty-two all-ceramic and three metal-ceramic crowns were cemented. The gruop comprised the first patients treated with the CeraOne prosthodontic concept. Results: Eight patients did not complete the study. Only one implant failed, giving a cumulative success rate for impla nts of 98.5%. The failed implant was replaced: a crown was cemented and then followed for 5 years without any complications. Four crowns were recorded as failures, giving a cumulative success rate for crowns of 93.7%. It should be observed that this result was very positive, as all crown failures were related to extraordinary causes and not one was a result of common bite forces or fatigue. The initial bone loss was in accordance with other studies on Branemark implants, and a stable situation was recorded after 2 years for the supporting bone around implants and adjacent teeth when the conical implants were excluded. Soft tissues around implants and adjacent teeth appeared healthy, and the cementation and the placement of the abutment shoulder in the peri-implant sulcus did not cause any recession of the peri-implant mucosa. Conclusion: CeraOne experienced virtually no complications and proved to be a highly predictable and safe prosthodontic concept. CeraOne also eliminated problems with abutment screw loosening and crated a platform for good esthetic results and satisfied patients.

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2015 Quintessence Publishing Co Inc

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog