Reduction of Implant Loading Using a Modified Centric Occlusal Anatomy


Pages: 55-69
PMID: 9588992

Purpose: This paper focues on the derivation of implant loading forces as influenced by occlusal anatomy. Vertical occlusal forces on cusp inclines produce resultant lines of force that result in lateral rather than vertical forces to the supporting bone. Materials and Methods: An analysis of resultant lines of force with different impacting occlusal surfaces was illustrated. Methods were suggested to decrease implant laoding by reducing cusp inclines, utilization of cross occlusion, and the modification of occlusal anatomy to provide a continuous 1.5-mm flat fossae, rather than the line angles of the usual cuspal anatomy. The relationship of incisal guidance to the cusp inclines on the adjustable articulator were reviewed. Modification of the incisal pin and articulator settings were suggested to produce a 1.5-mm fossae throughout teh prosthesis. Practical laboratory and intraoral occlusal adjustment techniques were suggested to provide a modified centric occlusal anatomy to help decrease implant loading. Results: Clinical examples were shown to verify the accuracy of the modified settings on the semi-adjsutable articulator and the resultant modified occlusal anatomy. Conclusion: Implant loading can be reduced by modifying the location of the impact area and the occlusal anatomy. Simple modification of the incisal pin and articulator settings can be used to produce a 1.5-mm flat fossae, which results in more vertical forces to the supporting bone. The same procedures are used to reduce cusp inclinations, which effectively lessens the torque exerted on the prosthesis, implant, and bone. A combination of all these factors can prevent implant overload

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2015 Quintessence Publishing Co Inc

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog