Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
November/December 1999
Volume 12 , Issue 6

Back
Share Abstract:

New Approach for Evaluating Metal-Porcelain Interfacial Bonding

Napa Suansuwan, BSc, DDS, Grad Dip Clin Sc, MSc/Michael Vincent Swain, BSc (Hons), PhD

Pages: 547-552
PMID: 10815609

Purpose: The purpose of this study was to evaluate the bonding characteristics of porcelain-fused-to-metal (PFM) systems by determining the strain energy release rate associated with interface fracture of porcelain and metals. Materials and Methods: Porcelain-veneered metal plates cast from commercially pure titanium and 3 metal alloys (gold, palladium, and nickel-chromium alloys) were made to dimensions of 25 mm 3 8 mm 3 2.5 mm with comparable thicknesses of porcelain and metal. The porcelain side of the specimens was notched to the interface with a thin diamond saw, and a small precrack was initiated at the metal-porcelain interface. The samples were subjected to a limited number (typically less than 4) of load-unload cycles under 4-point bending at a crosshead speed of 0.1 mm/min. The loading and unloading force displacements associated with stable crack extension were recorded. The strain energy release rate was calculated. The interfacial area was also examined under scanning electron microscope (SEM) after the test. Results: The mean strain energy release rates were 72.7 10.0 J/m2, 58.5 13.5 J/m2, 39.4 4.3 J/m2, and 16.6 2.5 J/m2 for the samples of gold, palladium, nickel-chromium alloys, and titanium, respectively. The SEM photographs showed that the crack occurred in the porcelain layer close to the interface. Conclusion: The bonding characteristics of PFM systems were determined with 3 types of metal alloys and commercially pure titanium by a fracture mechanics approach. The gold alloy and titanium are considered to obtain the greatest and least adhesion, respectively. The test system has proven to be a simple and reliable approach to determine the bonding in bimaterial systems.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog