Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
November/December 1999
Volume 12 , Issue 6

Back
Share Abstract:

Outcome of Single-Unit Metal-Ceramic Crowns

Terry R. Walton, BDS, MDSc (Syd), MS (Mich), FRACDS

Pages: 519-526
PMID: 10815605

Purpose: The purpose of this study was to report on the clinical characteristics and outcome of 688 single-unit metal-ceramic crowns placed in a specialist prosthodontic practice between January 1984 and December 1992. Materials and Methods: Clinical and laboratory techniques were standardized and patients were recalled by the author between June and December of 1993. The outcome of all crowns was allocated to one of 6 fields in this assessment period. Results: Clinical review examination by the author covered 87% of the crowns. Of these, 52% had been in service for 5 to 10 years and 48% for less than 5 years but more than 1 year; 67% of the crowns were placed on vital teeth and 94% were given a ’good prognosis’ rating at examination. The repair and failure rates of crowns in the 5 to 10 years in clinical service group were both 3%. Crowns on nonvital teeth in the same grouping had a significantly greater failure rate (5%) than crowns on vital teeth (1%), and anterior teeth had a significantly greater retreatment rate than posterior teeth. Retreatment for all 25 crowns occurred within 66 months after cementation. Tooth fracture accounted for 56% of retreatments, while caries and loss of retention accounted for only 24% of retreatments; 2% of initially vital teeth were endodontically treated during the survey period. Conclusion: Single-unit metal-ceramic crowns have a high expectancy of exceeding 10 years of clinical service when the described clinical and laboratory protocol is applied.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog