In Vitro Fracture Force and Marginal Adaptation of Ceramic Crowns Fixed on Natural and Artificial Teeth

Martin Rosentritt, MS/Tobias Plein, DDS/Carola Kolbeck, DDS/Michael Behr, DDS, PhD/Gerhard Handel, DDS, PhD

Pages: 387-391
PMID: 11203659

Purpose: Artificial teeth made of acrylic resin or alloy are considered substitutes for rare caries-free human teeth in in vitro examinations. The purpose of this study was to compare the fracture strength and marginal adaptation of all-ceramic single crowns fixed to natural teeth with crowns fixed to artificial teeth after artificial aging. Materials and Methods: The fracture force and marginal adaptation were investigated in 28 adhesively luted all-ceramic crowns on human molars of different sizes, as well as on alloy and liquid crystal polymer (LCP) artificial teeth. The fracture force was determined using a universal testing machine, and the semiquantitative marginal adaptation was examined using a scanning electron microscope, in both instances after simulating 5 years of clinical service. Results: Fracture force was found to be significantly higher for crowns fixed on substitute materials (alloy = 1,838 N; LCP = 1,392 N) than for crowns on human teeth (888 N). No significant differences in marginal quality could be determined between the groups. All crowns showed marginal gaps of about 10% and perfect margins at about 90%. Conclusion: The high in vitro fracture values of all-ceramic crowns on artificial materials may lead to a misinterpretation of the tested restorative materials, overvaluing the material properties in a first preclinical estimation. Human teeth or materials with a comparable modulus of elasticity are therefore preferred in in vitro fracture tests.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog