Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
May/June 2009
Volume 22 , Issue 3

Back
Share Abstract:

Short-Term Bone Level Observations Associated with Platform Switching in Immediately Placed and Restored Single Maxillary Implants: A Preliminary Report

Luigi Canullo, DDSa,b/Giuseppe Goglia, DDSb/Giorgia Iurlaro, BScc/Giuliano Iannello, BScd

Pages: 277282
PMID: 19548410

Purpose: The aim of this study was to evaluate the short-term bone level response around immediately placed and provisionally restored implants using a platform switching concept. Materials and Methods: Twenty-two implants with a platform diameter of 5.5 mm were immediately placed in healthy maxillary sites in 22 patients. Resultant circumimplant spaces were filled with a mixture of bovine bone matrix and collagen. The implants were randomly divided into two equal groups: 11 implants connected with 3.8-mm-diameter abutments (test group) and 11 with 5.5-mm-diameter ones (control). Provisional crowns were adapted and adjusted for nonfunctional immediate placement on each implant and the final crowns were constructed 2 months later. Posttreatment assessments were carried out by an independent trained observer at the time of implant placement (baseline), at definitive prosthesis insertion, and every 6 months thereafter. These assessments included periapical radiographs, pocket probing depths (PPD), bleeding on probing (BOP), and modified Plaque Index (mPlI) on both implants and first proximal teeth. An image analysis software application was used to compare the bone crestal heights at the mesial and distal aspects of the implants. Results: The mean follow-up observation period was 25 months and all implants were judged to be successfully osseointegrated. In the test group, radiographic analysis showed an average bone reduction level of 0.30 mm (SD = 0.16 mm). This mean value was statistically significantly different (P ≤ .005) from the average reduction in the control group (mean = 1.19 mm, SD = 0.35 mm). No differences between the two groups in PPD, BOP, or mPlI were found. Conclusion: This preliminary study suggests that immediate single implant restorations in specific maxillary sites with subsequent platform switching may provide peri-implant alveolar bone-level stability. Int J Prosthodont 2009;22:277282.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog