Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
January/February 2009
Volume 22 , Issue 1

Back
Share Abstract:

Ceramic Pressed to Metal Versus Feldspathic Porcelain Fused to Metal: A Comparative Study of Bond Strength

Bhavani Venkatachalam, DMD, MS/Gary R. Goldstein, DDS/Mitchell S. Pines, DDS/Eugene L. Hittelman, MA, EdD

Pages: 94100
PMID: 19260436

Purpose: The aim of this study was to compare the debond/crack initiation strength (D/CIS) of a leucite-based low-fusing ceramic pressed (PC) to metal and feldspathic porcelain (FP) fused to metal. Materials and Methods: Forty rectangular metal specimens, 20 noble alloy (NA; gold-palladium) and 20 base metal alloy (BA; cobalt-chromium) were fabricated per ISO 9693:1999 standards (25.0 mm 3 0.5 mm 3 3.0 mm). Ten samples in each group received FP and the remaining 10 received PC. The samples in the PC group underwent wax pattern build-ups and subsequent investing and casting. The ceramic dimensions in all four groups were 8.0 mm 3 1.0 mm 3 3.0 mm. The final metal-ceramic specimen thickness was 1.5 mm. All specimens were subject to the Schwickerath crack-initiation three-point bending test at a crosshead speed of 1.5 mm/min. Metal-ceramic fracture loads were recorded in Newtons and D/CIS was calculated using the formula: tb = k × Ffail. Results: Mean D/CIS were as follows: BA-FP: 36.11 2.31 MPa, NA-FP: 42.64 1.94 MPa, BA-PC: 37.47 6.02 MPa, and NA-PC: 47.94 3.92 MPa. A 2-way ANOVA revealed no significant difference in D/CIS values between the four groups. A statistically significant difference was noted when comparing the mean D/CIS values obtained between the two metal alloys used (NA: 45.29 MPa and BA: 36.79 MPa). Conclusion: No differences (P > .05) in mean D/CIS were found between the low-fusing ceramic pressed to metal and the FP fused to metal. A higher mean D/CIS (P > .05) was found for the NA compared to the BA, with both ceramics tested. Int J Prosthodont 2009;22:94100.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog