Effect of Proximal Wall Height on All-Ceramic Crown Core Stress Distribution: A Finite Element Analysis Study

Paulo G. Coelho, DDS, PhD/Nelson R. Silva, DDS, PhD/Van P. Thompson, DDS, PhD/E. Dianne Rekow, DDS, PhD/Guangming Zhang, PhD


PMID: 19260434

Purpose: Mechanical analyses of idealized crown-cement-tooth systems through finite element analysis (FEA) has provided valuable insight concerning design parameters and materials that favor lower stress patterns. However, little information regarding variation of basic preparation guidelines in stress distribution has been available. The primary objective of this study was to evaluate maximum principal stresses on a molar crown veneer plus core system natural tooth configuration preparation with variations in the ratio of proximal axial length (PAL) to buccal axial length (BAL) as well as loading condition and position. Materials and Methods: Three-dimensional models comprising a crown veneer (porcelain), crown core (zirconia), cement layer, and tooth preparation (4.2 mm BAL with PAL reductions of 0.8 mm, 1.0 mm, and 1.2 mm) yielding BAL:PAL ratios of 1.23, 1.31, and 1.4 were designed by computer software (Pro/Engineering). The models were imported into an FEA software (Pro/Mechanica), with all degrees of freedom constrained at the root surface of the tooth preparation. Each tooth preparation crown configuration was evaluated under a vertical (axial) 200 N load, and under a combined vertical 200 N and horizontal (buccally) 100 N load applied at different positions from the central fossa to the cusp tip. Maximum principal stress (MPS) was determined for the crown core for each crown BAL:PAL ratio, loading condition, and position. Results: Under both vertical and combined loading conditions, the highest MPSs were located at the occlusal region and in the occlusogingival region of the ceramic core. MPS values increased in the proximal region as the BAL:PAL ratio increased. Combined loading resulted in a general increase in MPS compared to vertical loading. Conclusion: Increasing the BAL:PAL ratio (reducing the proximal axial length of the preparation) acted as a stress concentrator at regions near the crown margins, suggesting this area may be vulnerable to damage from fit adjustment as well as during function. Such increases in stress concentration should be considered in clinical scenarios, especially when inherent flaws are present in the material, since extensive high-magnitude tensile stress fields have been noted under all loading conditions.Int J Prosthodont 2009;22:7886.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help