On a New Method to Assess the Accuracy of a CAD Program

Karin I. Dahlmo, BS, CDT, Matts Andersson, LDS, Odont Dr/PhD, Martin Gellerstedt, PhD, Stig Karlsson, LDS, Odont Dr/PhD

Pages: 276-283
PMID: 11484578

Purpose: This study was initiated with the purpose of developing and evaluating a system for measuring the magnitude of the variation between a computer-aided design (CAD) object created on the computer screen and a replicated object produced by computer-aided manufacturing (CAM). Materials and Methods: Controlled geometric forms, a square and a cone, were designed in a CAD program, and measuring distances were selected. The CAD data were transmitted to CAM data, and objects were produced. The CAD/CAM process was the Procera system, and the holder system permitted the objects to be ground into cross sections, similar to the visualization in the CAD program. Five objects of each shape were produced and measured by two operators two times. Three operators measured one of the objects 30 times. Results: Observed values were greater than the true value. For all objects, the systematic error was at most 15.5 Ám. Interoperator difference was small. The variation because of measurement error was greater for the square object compared to the cone. However, the variation because of object was higher for the cone object than for the square. The total standard deviation was 7.7 Ám. Thus, the total random error caused by object variation and measurement error was in approximately 95% of all measurements less than 15 Ám. Conclusion: There are no differences in the measurement data derived from this method and actual measurement data from an object created by the computer-aided dental design program. The method has high validity and reliability, ie, high accuracy. Int J Prosthodont 2001;14:276-283.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog