Clinical Survey of Acrylic Resin Removable Denture Repairs with Glass-Fiber Reinforcement

Katja K. Narva, DDS, Hans Helenius, MSc, Antti Yli-Urpo, DDS, PhD

Pages: 219224
PMID: 11484568

Purpose: The aim of this study was to evaluate clinical usefulness and durability of continuous glass-fiber reinforcement in repair of acrylic resin removable dentures. Materials and Methods: Fractured removable dentures without reinforcement, with conventional metal-wire reinforcement, or with mesh reinforcement were collected from two dental schools in Finland. The total number of dentures was 51 and the number of patients was 48. During the repair, the dentures were reinforced with a polymer-preimpregnated E-glass fiber at the region of the fracture. The fibers were used as partial fiber reinforcement, ie, only the weakest part of the denture was reinforced. Follow-up time varied from 4 months to 4.1 years. After the follow-up period, possible fractures and discoloring were visually inspected. Possible irritation of oral mucosa by glass fibers and the general shape of the denture were also evaluated. Results: In 88 % of the cases, there was no need for adjustment at the region of partial fiber reinforcement, and the clinical condition of the dentures was good. Glass fibers did not irritate the oral mucosa. In the case of refracture or hairline fracture, positioning of the partial fiber reinforcement was incorrect or the reinforcement had been used incorrectly (the wetting of the reinforcement with denture base resin was inadequate). Conclusion: Polymer-preimpregnated partial fiber reinforcement seems to be useful in eliminating fractures of acrylic resin removable dentures. However, this study emphasizes the importance of correct positioning and accurate laboratory technique when partial fiber reinforcement is used. Int J Prosthodont 2001;14:219224.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog