Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
March/April 2001
Volume 14 , Issue 2

Back
Share Abstract:

Accuracy of Mechanical Digitizing with a CAD/CAM System for Fixed Restorations

Ralph G. Luthardt, Dr Med Dent, Olaf Sandkuhl, Dipl Ing, Volker Herold, Dr Ing Habil, Michael H. Walter, Prof Dr Med Dent

Pages: 146151
PMID: 11843451

Purpose: Most research on the accuracy of dental computer-aided design/manufacturing (CAD/CAM) systems focuses on the marginal gap. A detailed analysis of the various components of CAD/CAM systems (digitizer, software, and milling machine) using this approach is nearly impossible. The purpose of this study was to determine the accuracy of the manual mechanical digitizer of the Precident-DCS system. Materials and Methods: Gauge blocks were aligned to the coordinate planes of the digitizer to determine the point and length measurement uncertainty. The values for each measuring point were compared for statistical differences concerning first versus second operator, pressure, and mode of sensing using analysis of variance. The measurement uncertainty was given by 95th percentiles. Results: The mean one-dimensional point measurement uncertainty in the Y direction was 11 m for the first, 8 m for the second, and 37 m for both operators. The three-dimensional point measurement uncertainty in the Y direction was 10 m for the first, 33 m for the second, and 60 m for both operators. The point measurement uncertainty was significantly influenced by the pressure during sensing and by the operator as well. There were significant differences between the first and second recordings. The length measurement uncertainty in the Y direction for a gauge block of 20 mm was 52 m for both operators. Conclusion: The reliability of the manually guided Precident-DCS digitizer is limited because of the significant influence of the operator and the mode of sensing (one or three dimensional). Compared with an automatic digitizing system, the measurement uncertainty of the manually guided digitizer exceeds the values published in the literature. Int J Prosthodont 2001;14:146151.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog