Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
March/April 2001
Volume 14 , Issue 2

Back
Share Abstract:

Fracture Resistance of All-Ceramic and Metal-Ceramic Inlays

Josephine F. Esquivel-Upshaw, DMD, MS, Kenneth J. Anusavice, PhD, DMD, Megan Reid, Mark C. K. Yang, Robert B. Lee

Pages: 109114
PMID: 11843445

Purpose: Metal-ceramic inlay designs were developed to determine if the esthetic qualities of all-ceramic inlays could be duplicated and at the same time improve their strength and stability. The objectives of this study were to: (1) compare the fracture resistance of metal-ceramic inlays with that of all-ceramic inlays; (2) determine the correlation between the degree of preparation taper and fracture resistance; and (3) determine the correlation between marginal gap width and fracture resistance. Materials and Methods: Inlay preparations were made on 60 Dentoform teeth, with 30 teeth allocated for metal-ceramic inlays and 30 teeth for all-ceramic inlays. Each group was further subdivided into 5-, 10-, and 20-degree taper preparations. Metal-ceramic inlays were fabricated using Goldtech Bio 2000 metal and Ceramco porcelain extending to the margin, while all-ceramic inlays were made from Empress II ceramic. Marginal gap widths were measured at six critical areas after fabrication. The load at failure was measured using an Instron Universal Testing Machine. Results: The mean fracture load for all-ceramic inlays and metal-ceramic inlays at 5, 10, and 20 degrees was 70 40 N, 48 37 N, 33 7 N, and 40 23 N, 29 22 N, and 14 4 N, respectively. The mean gap width was 105 m and 126 m for all-ceramic and metal-ceramic inlays, respectively. Conclusion: The mean fracture load for Empress inlays was significantly higher than that for metal-ceramic inlays. Inlays with a 5-degree taper were significantly more fracture resistant than those with a 20-degree taper. There was no relation between marginal gap width and fracture resistance. Int J Prosthodont 2001;14:109114.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog