Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
March/April 2008
Volume 21 , Issue 2

Back
Share Abstract:

Occlusal Wear of Metal-Free Ceramic-Filled Polymer Crowns After 2 Years in Service

Thomas Stober, Dr Med Dent/Jens Dreyhaupt, Dr Rer Nat/Ute Lehnung, Dr Med Dent/Peter Rammelsberg, Prof Dr Med Dent

Pages: 161165
PMID: 18546773

Purpose: Improvements in the physical properties of modern composites have led to continuous expansion of their field of application to include extensive, occlusion-bearing posterior restorations and even metal-free polymer crowns. The objective of this clinical study was to investigate the influence of gender, arch, and crown location on the occlusal wear of metal-free ceramic-filled polymer crowns and to compare their wear with the mean annual occlusal wear of enamel (15 to 38 m). Materials and Methods: One hundred fourteen ceramic-filled polymer crowns made of Artglass (Heraeus Kulzer) were placed in 74 patients. After 1 year, 93 crowns were available for wear measurement. After 2 years, 76 crowns were available. Wear was determined by use of replicas. A 3-dimensional optical profilometer (Laserscan 3D, Willytec) was used to digitize and superimpose the occlusal surfaces of the baseline and recall replicas (occlusal matching). Results: After 1 year, median wear of the entire occlusal surface was 19 m for anterior and canine teeth, 19 m for premolars, and 21 m for molars. After 2 years, median wear was 36 m for anterior and canine teeth, 44 m for premolars, and 84 m for molars. The wear of the occlusal contact areas was significantly higher. Significant effects of crown location (premolar or molar) on the extent of wear of the occlusal contact areas were found. Conclusions: Ceramic-filled polymer crowns are subject to measurable occlusal wear that exceeds that of natural enamel. Int J Prosthodont 2008;21:161165.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog