Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
March/April 2008
Volume 21 , Issue 2

Back
Share Abstract:

Four-Year Clinical Performance of a Lithia Disilicate–Based Core Ceramic for Posterior Fixed Partial Dentures

Josephine F. Esquivel-Upshaw, DMD, MS/Henry Young, DDS/Jack Jones, DMD/Mark Yang, PhD/Kenneth J. Anusavice, PhD, DMD

Pages: 155–160
PMID: 18546772

Purpose: The objective of this research was to test the hypothesis that 3-unit fixed partial dentures (FPDs) made from a moderately high-strength core ceramic will adequately resist fracture in posterior regions if fabricated with a minimal connector size of 4 mm. Materials and Methods: Thirty ceramic FPD core frameworks were prepared using a hot-pressing technique and a lithia disilicate–based core ceramic. The maximum occlusal force was measured for each patient prior to tooth preparation. Connector heights and widths were measured for each FPD. Patients were recalled annually after cementation for 4 years and evaluated using 11 clinical criteria. All FPDs were examined by 2 independent clinicians, and rankings for each criterion were made from 1 to 4 (4 = excellent; 1 = unacceptable). Results: The fracture rate was approximately 3% per year, and the proportion of good overall ratings in the nonfractured FPDs was reduced by more than 6% per year, where a good overall rating was defined to be a rank of 3 or 4 in all 11 criteria. There was little evidence that the use of either resin-reinforced glass-ionomer cement (Protec CEM) or dual-cure resin cement (Variolink II) made any difference in terms of fracture rate or overall rating (P = .30, .63, .97, and .71 for the 4 years, respectively). From a fracture resistance perspective, 4 of the 30 ceramic FPDs fractured within the 4-year evaluation period, representing an 86.7% success rate. Another FPD was replaced because of a caries lesion on 1 abutment tooth away from the margin. One FPD fracture was associated with the subject having the greatest occlusal force (1,031 N). The other 2 fractures were associated with FPDs that exhibited connector heights of less than 3 mm. All criteria were ranked good to excellent during the 4-year period for the remaining FPDs. Conclusion: Fractured FPDs were associated with a connector height of less than 4 mm; thus, the hypothesis was accepted. Int J Prosthodont 2008;21:155–160.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog