LOGIN
 
Share Page:
Back

Volume 20 , Issue 5
September/October 2007

Pages 463464


Efficacy of High-Level Microwave Disinfection of Dental Gypsum Casts: The Effects of Number and Weight of Casts

Einar Berg, BDS, Dr Odont / Oyunn Nielsen / Nils Skaug, DDS, Dr Odont


PMID: 17944332

The aim of this study was to determine if the bactericidal effect of microwaving gypsum casts is maintained at maximum capacity of the oven (16 casts). Batches of 8 and 16 gypsum casts made from in vivo impressions were divided in half. One half of each cast was microwaved at 900 W for 5 minutes. The remaining halves were left untreated. When assessed for bacteriological growth, the median cfu/mL of the untreated casts was between 105 and 106, while the microwaved casts showed a cfu/mL of 0, indicating that microwaving as described will disinfect gypsum casts even at maximum capacity of the oven. Int J Prosthodont 2007; 20:463464.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 