Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
November/December 2005
Volume 18 , Issue 6

Back
Share Abstract:

A Systematic Review of the Scientific Documentation of Fixed Partial Dentures Made from Fiber-Reinforced Polymer to Replace Missing Teeth

Asbjørn Jokstad, LDS, Dr Odont, PhD/Meriç Gökçe, LDS/Carl Hjortsjö, LDS

Pages: 489–496
PMID: 16335168

Purpose: Many restorative systems have become commercially available that are based on fiber-reinforced polymers (FRP) for production of fixed partial dentures. However, the clinical documentation of their use has not been systematically reviewed and critically appraised. This systematic review aimed to identify the scientific documentation of all commercially available products within this material group. Materials and Methods: MEDLINE was searched for all clinical and laboratory studies on FRP, and papers were browsed to identify product names. Moreover, the Internet was searched to find manufacturers of FRP products. Also, several large trade exhibitions were visited to identify products and manufacturers. All papers that included any data from a clinical setting of an identifiable product were critically appraised. Each product was categorized according to the scientific clinical documentation of their intended clinical use. Results: Eleven commercial products were identified. The scientific clinical documentation of these products varied markedly, but was generally poor. No randomized controlled trials have been carried out on FRPs versus, eg, conventional treatments, nor are any long-term cohort studies available. None of the products demonstrate good evidence for usage as a technical solution to permanently replace lost teeth. Conclusion: The use of FRP for fixed partial dentures must still be regarded as experimental. Int J Prosthodont 2005;18:489–496.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog