Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
March/April 2005
Volume 18 , Issue 2

Back
Share Abstract:

Influence of Self-Etching Primer Preapplication on the Dentin-Titanium Shear Bond Strength Mediated by a Resin-Modified Glass-Ionomer Cement

Estelle Schittly, DDS/Catherine Besnault, DDS, PhD/Denis Bouter, DDS, PhD/N. Dorin Ruse, MSc, PhD, MCIC/Michel Degrange, DDS, MSc, PhD/Jean-Pierre Attal, DDS, PhD

Pages: 112116
PMID: 15889658

Purpose: The aims of this study were to evaluate the in vitro shear bond strength of the dentin-titanium interface mediated by Fuji Plus, a resin-modified glass-ionomer cement, applied in combination with several self-etching bonding systems, and to compare the values obtained with those of SuperBond, chosen as a reference luting agent. Materials and Methods: The self-etching bonding systems used in combination with Fuji Plus were AdheSE, Xeno III, Clearfil SEBond, Unifil Bond, and an experimental self-etching bonding system comprising the sequential application of Xeno III and the bonding component of SE Bond. Two control groups were also tested: a negative control with Fuji Plus along with its conditioner (10% ferric chloride, 2% citric acid solution); and a positive control with the resin cement SuperBond. One hundred five human molars were used to prepare seven groups of fifteen samples each. The samples were tested in shear after 7-day storage at 100% relative humidity and 37C. Results and Conclusion: Three of the tested combinations of self-etching bonding systems with Fuji Plus significantly improved in comparison with the negative control group, from 9% to 44%. The self-etching bonding systems obtained using Fuji Plus in combination with Clearfil SEBond, Unifil Bond, and the experimental system were not different from those obtained with SuperBond. Int J Prosthodont 2005;18:112116.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog