Water Sorption and Dimensional Stability of Three Glass Fiber–Reinforced Composites

John Chai, BDS, MS, MJ, DLaw/Yutaka Takahashi, DDS, PhD/Kazuhiro Hisama, DDS, PhD/Hiroshi Shimizu, DDS, PhD

Pages: 195–199
PMID: 15119871

Purpose:Water sorption and dimensional stability of three fiber-reinforced composites were studied. Two composites (Vectris, FibreKor) were resin impregnated industrially, and one composite (Stick) was polymer preimpregnated but required further manual impregnation. Materials and Methods:Bar-shaped specimens of each material were prepared according to manufacturers’ instructions. The water sorption and dimensional change of each specimen were calculated according to the change in its weight and dimension before and after immersion. Specimens were immersed in distilled water for 1, 7, 60, and 180 days. SEMs were taken to examine the quality of the fiber-matrix interface. The volume percentage of fiber content of each fiber-reinforced composite was experimentally estimated. Results:A general trend of increasing water sorption for each immersion period according to the material type was: Vectris  FibreKor  Stick. There were no significant differences in dimensional change among the materials and immersion periods. Conclusion:The preimpregnated fiber-reinforced composite (Stick) showed higher water sorption than the industrially impregnated fiber-reinforced composites (Vectris, FibreKor). Despite a variation in the water sorption of the fiberreinforced composites studied, all were within a 32 µg/mm3 criterion established by the ISO. The magnitude of dimensional change was small enough that it should not raise any significant clinical concern. Int J Prosthodont 2004;17:195–199.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog