Home Subscription Services
 
   

 
The International Journal of Prosthodontics
IJP Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: IJP
The International Journal of Prosthodontics

Edited by George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

ISSN 0893-2174

Publication:
September/October 2013
Volume 26 , Issue 5

Back
Share Abstract:

Three-Dimensional Accuracy of CAD/CAM Titanium and Ceramic Superstructures for Implant Abutments Using Spiral Scan Microtomography

Rahul Prasad, MDS/Abdulaziz Abdullah Al-Kheraif, PhD

Pages: 451457
PMID: 23998143
DOI: 10.11607/ijp.3302

Purpose: To introduce a new three-dimensional (3D) method of evaluating the fit of implant superstructures made using computer-aided design/computer-assisted manufacture (CAD/CAM) technology and conventional casting and to determine which biomaterial would produce optimal fit for the long-term clinical longevity of dental implant restorations. Materials and Methods: Five groups of materials were used to make 50 copings (n = 10) using CAD/CAM technology for titanium, partially sintered zirconia, fully sintered zirconia, and leucite-reinforced glass-ceramic materials and a conventional casting technique for the nickel-chromium group. The vertical marginal gap was measured at 16 equidistant points using a traveling microscope and compared with the 3D spatial gap values obtained by using spiral scan microtomography. Multivariate analysis of variance and Tukey post hoc tests were used for statistical analysis. Results: The vertical marginal gap width ranged from 13.21 to 75.26 μm for the CAD/CAM groups and 64.89 to 115.27 μm for the conventionally casted group. The spatial gap ranged from 0.22 to 0.67 mm3 for CAD/CAM groups and 0.75 to 0.89 mm3 for the conventionally casted group. The highest accuracy of fit was observed in the titanium group, followed by the leucite-reinforced glass-ceramic, partially sintered zirconia, fully sintered zirconia, and nickel-chromium groups. Conclusion: When used in combination with the CAD/CAM technique, titanium produces the most accurate implant superstructure. Spiral scan microtomography can be used to measure the accuracy of fit of dental implant superstructures and restorations as it provides a 3D measurement with less chance of errors compared with conventional methods of measurement. Int J Prosthodont 2013;26:451457. doi: 10.11607/ijp.3302

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog