Evaluation of the Fit of CAD/CAM Abutments

Adam Hamilton, BDSc, FRACDS, DCD/Roy B. Judge, BDS, LDS, RCS, MDSc, PhD/Joseph E. Palamara, BDSc, Dip Ed, PhD/Christopher Evans, BDSc (Hons), MDSc, MRACDS


PMID: 23837169
DOI: 10.11607/ijp.3501

Purpose: This study aimed to compare the fit of computer-aided design/computerassisted manufacture (CAD/CAM) abutments provided by a single system with proprietary prefabricated abutments on various implant systems. Materials and Methods: Titanium CAD/CAM abutments were compared with prefabricated abutments on five different implant types. The samples were embedded in epoxy resin, sectioned longitudinally, and polished. Scanning electron microscopy was used to measure the gap between the implants and abutments at the connecting flanges and internal features. Independent t tests were used to compare data. Results: A mean difference of 1.86 μm between the gold synOcta and CAD/CAM abutments on the Straumann Standard Plus implant was observed to be statistically significant (P = .002). Less than 0.4 μm of difference was found between the CAD/CAM and prefabricated abutments for the remaining implant types, and statistical significance was not observed. Mean differences of 34.4 μm (gold) and 44.7 μm (titanium) were observed between the CAD/ CAM and prefabricated abutments on the Straumann Standard Plus implants, which were statistically significant (P < .001). A mean difference of 15 μm was also observed between the CAD/CAM and prefabricated abutment on the NobelReplace implant, which was statistically significant (P = .026). All other groups had less that 4 μm of difference, and statistical significance was not observed. Conclusion: The CAD/CAM abutments appeared to have a comparable fit with prefabricated abutments for most of the systems evaluated. Design differences between the abutment connections for both Straumann implants were observed that affected the fit of internal components of the implant-abutment connections. Int J Prosthodont 2013;26:370380. doi: 10.11607/ijp.3501


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help