Can Resonance Frequency Analysis Predict Failure Risk of Immediately Loaded Implants?

Momen A. Atieh, BDS, MSc, PhD/Nabeel H.M. Alsabeeha, DMD, MSc, MFDS RCPS, PhD/Alan G.T. Payne, BDS, MDent, DDSc, FCD

Pages: 326-339
PMID: 22720282

Purpose: Resonance frequency analysis (RFA) is used to measure oral implant stability. There is controversy with regard to its accuracy in predicting both implant stability and osseointegration. This systematic review and meta-analysis determined the prognostic accuracy of RFA in predicting implant failure following immediate loading protocols. Materials and Methods: MEDLINE, EMBASE, the Cochrane Oral Health Group’s Trials Register, the United Kingdom National Research Register, the Australian New Zealand Clinical Trials Registry, the Database of Abstracts of Reviews of Effectiveness, and the Conference Proceedings Citations Index were searched to select studies that used RFA in assessing implant stability prior to immediate loading. The sensitivity, specificity, and accuracy of RFA in the selected studies were evaluated using a random effects model. The summary receiver operating characteristic was constructed to summarize the overall test performance. Results: Fifteen studies with 2,236 immediately loaded implants were identified. The sensitivity of RFA in predicting failure of immediately loaded implants was 0.38 (95% confidence interval [CI]: 0.22 to 0.56), the specificity was 0.73 (95% CI: 0.71 to 0.75), and the diagnostic odds ratio was 2.10 (95% CI: 0.79 to 5.57). The area under the curve was 0.54, suggesting a poor predictive and discriminative ability. Conclusion: RFA measurement at the time of implant placement is not sufficiently accurate to determine implant stability and osseointegration during immediate loading protocols. Int J Prosthodont 2012;25:326–339.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog