LOGIN
 
Share Page:
Back

Volume 25 , Issue 2
March/April 2012

Pages 166169


Strain Development of Screw-Retained Implant-Supported Fixed Restorations: Procera Implant Bridge Versus Conventionally Cast Restorations

Matthias Karl, PD Dr Med Dent/Stefan Holst, PD Dr Med Dent


PMID: 22371839

The aim of this study was to quantify the strain development of screw-retained three-unit implant-supported Procera Implant Bridge restorations. Two groups of screw-retained implant-supported restorations (n = 10) were fabricated by means of casting or computer-aided design/computer-assisted manufacture (CAD/CAM) to fit an in vitro cast situation with two implants. During fixation of the restorations, the emerging strains were recorded using strain gauges attached to the cast material mesially and distally adjacent to the implants. Absolute mean strain development ranged from 29.35 m/m to 2,665.80 m/m at the different strain gauge locations. Fabrication method had a significant effect on strain development (multivariate analysis of variance, P = .000), with the cast restorations showing significantly higher strain levels compared to the CAD/CAM-fabricated superstructures. CAD/CAM fabrication of screw-retained implant-supported restorations provides greater passivity of fit compared to conventional fabrication methods such as casting. Int J Prosthodont 2012;25:166169.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help