Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
EJED Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
Official Site
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: EJOI

 

European Journal of Oral Implantology

Editor in Chief: Dr. Marco Esposito

Official publication of the British Society of Oral Implantology (BSOI) and the Dutch Society of Oral Implantology (NVOI)

ISSN (print) 1756-2406 • ISSN (online) 1756-2414

Publication:

Summer 2008
Volume 1 , Issue 2

Back
Share Abstract:

Immediate versus early loading of flapless-placed implants supporting maxillary full-arch prostheses: a randomised controlled clinical trial

Cannizzaro, Gioacchino / Torchio, Cinzia / Leone, Michele / Esposito, Marco

Purpose: To evaluate the efficacy of flapless placed implants immediately or early loaded at 2 months with full-arch prostheses. Materials and methods: Thirty patients were randomised: 15 to the immediately loaded group and 15 to the early loaded group. All implants had to be inserted with a minimum torque > 48 Ncm. Outcome measures were prosthesis and implant failures, biological and biomechanical complications, peri-implant marginal bone level changes, patient satisfaction and implant stability quotient (ISQ) assessed with a resonance frequency analysis instrument. Results: Ninety implants were placed in the immediately loaded and 87 in the early loaded group. Four localised flaps had to be elevated. Six implants in five patients did not reach the planned insertion torque. Four were immediately replaced by larger diameters ones, one was early loaded and another removed just after placement. After 1 year no drop-out occurred. One implant failed in the immediately loaded group versus three early loaded implants in two patients. There were no statistically significant differences between groups for implant losses, complications, and mean marginal bone level changes. There were borderline significant differences for mean ISQ values, and patients in the immediately loaded group were significantly more satisfied than those early loaded. When comparing mean ISQ values taken 2 months after placement with year 1 data within each group, values increased significantly. Conclusions: Maxillary cross-arch prostheses can be successfully loaded the same day of flapless implant placement, increasing patient satisfaction while decreasing treatment time and patient discomfort. No apparent advantages were seen when loading implants at 2 months.

Keywords: dental implants, edentulous maxillae, early loading, flapless, immediate loading

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog