Home Subscription Services
 
   

 
The Chinese Journal of Dental Research
About the Editor
Editorial Board
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
Official Site
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: CJDR

 

The Chinese Journal of Dental Research

Edited by Xu Chen MA

Official journal of the Chinese Stomatological Association

ISSN (print) 1462-6446 • ISSN (online) 1867-5646

Publication:

Fall 2010
Volume 13 , Issue 2

Back
Share Abstract:

Effects of Background, Direction and Intensity of Ambient Light, Measuring Position, and Adjacent Teeth, on Anterior Tooth Colour Measurement In Vitro

Ma, Jian Feng / Du, Ruo Xi / Wang, Si Qian / Li, Yi Ming

Pages: 147 - 152

Objective: To investigate the effects of different background colours (black, white or pink), direction and intensity of ambient light, measuring position, and the adjacent teeth, on the in vitro colour measurement of maxillary anterior teeth, using the Minolta CR-321 colorimeter. Methods: Ten extracted human maxillary central incisors were selected. A fibre-optic light MI-150 was used as the ambient illuminant. Teeth were irradiated from a 3- or 12-o’clock direction. L*a*b* values of seven sites on the labial surfaces were obtained by means of the Minolta CR-321 colorimeter, using three background colours, with or without the adjacent teeth. The recorded data were analysed with two-tailed Student t tests and analysis of variance (α = 0.05). Results: The ambient light did not affect the colour measurement of anterior teeth, regardless of the presence or absence of the adjacent teeth. There were no statistically significant differences in L*a*b* values at the same position under different background colours, except ΔE12 (colour difference between site 1 and site 2) between black and white backgrounds. ΔE12 (under black background), ΔE13 and ΔE15 were greater than 1.5, while the others were lower than 1.5. Conclusion: The background, ambient light and the presence of adjacent teeth did not affect the colour measurement of anterior teeth using the Minolta CR-321 colorimeter in vitro. The inherent disadvantages of using the naked eye during clinical visual shade assessment may be overcome by the colorimeter.

Keywords: background colour, colorimeter, colour measurement, in vitro, tooth colour

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog