Quintessence Publishing Publisher of professional dental  journals, books, and multimedia
 
 
 
Subscriber Access
Login
First Time User?
Forgot Your Password?
 
The International Journal of Oral & Maxillofacial Implants
JOMI Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
Online Store
Books
Journals
Videos and Multimedia
View Cart

Current Publication:
The International Journal of Oral & Maxillofacial Implants
July/August
Volume 25, Issue 4

Back

The Effect of Miniscrew Taper Morphology on Insertion and Removal Torque in Dogs

Jung-Yul Cha, DDS, PhD/Teruko Takano-Yamamoto, DDS, PhD/Chung-Ju Hwang, DDS, PhD

Purpose: This study compared the insertion and removal torque of tapered and cylindric orthodontic miniscrews. Materials and Methods: Ninety-six miniscrews were placed into the buccal alveolar bone of the mandible in six male beagle dogs. Maximum insertion torque was measured during placement of 48 miniscrews, and the maximum removal torque was recorded after 3 and 12 weeks of loading. After 4 months of healing, 48 additional miniscrews were implanted in almost the same place as the first set of implants; insertion torque was again measured. Histologic analysis was performed after 3 and 12 weeks of loading. Bone-implant contact and bone volume/total volume were compared during each period and in each group. Results: The tapered miniscrews showed a higher mean maximum insertion torque (22.3 ± 3.2 Ncm) than the cylindric miniscrews (13.6 ± 2.0 Ncm) (P < .001). The mean maximum removal torque of the tapered miniscrews (9.1 ± 2.3 Ncm) was significantly higher than that of the cylindric miniscrews (5.7 ± 2.2 Ncm) at 3 weeks after placement (P < .05), but there was no significant difference in the mean maximum removal torque value between the tapered (4.2 ± 1.4 Ncm) and cylindric (3.0 ± 1.1 Ncm) implants after 12 weeks of loading. The percentage of bone-implant contact was similar between the groups after 3 weeks of loading and increased later. The percentage of bone volume/total volume was higher in the tapered miniscrews than in the cylindric miniscrews after 3 weeks of loading (P < .05), but there was no significant difference between the groups after 12 weeks of loading. Conclusions: In this dog model, the tapered miniscrew design increased initial stability until 3 weeks of loading but had no additional effect on the secondary stability (ie, after 12 weeks of loading) versus a cylindric miniscrew design. Int J Oral Maxillofac Implants 2010;25:777–783

Key words: cylindric implant design, insertion torque, orthodontic miniscrew, removal torque, tapered implant design

View entire article
HTML
PDF

 

All Rights Reserved